Milk cooling gives off heat at every milking, but wash-down and cleaning need hot water later. Modular Thermal Tanks store recovered heat and off-peak heat pump output until it is needed, so water heating stays off the peak and demand charges come down.
Results depend on herd size, milking schedule, daily hot water use, electricity rates and installation. Case study figures on this page come from other commercial hot water projects, not dairy sites. Sizing, code and incentive decisions belong to the project's engineer, contractor, utility or tax advisor.

Published figures from Thermal Tank projects with heavy daily hot water demand. Each figure is quoted as it appears in that project's case study.
A resort in the U.S. Virgin Islands paired Thermal Tanks with heat pumps.
A Puerto Rico laundromat that runs hot water all day.
Cleveland Lofts, served from 12 Thermal Tanks and rooftop PVT.
A 350-gallon tank stores about 54.6 kWh. Tanks combine as demand grows.
Sources: published Thermal Energy HQ case studies. Results at a dairy depend on that farm's equipment, schedule and utility rates.
Refrigeration rejects heat while milk is being chilled, but much of a dairy's hot water is used at cleaning time. Storage bridges that gap, so recovered heat goes to work instead of into the air.
Thermal Tanks are unpressurized. The stored water works as a heat battery, and heat moves in and out through heat exchangers.
Charge the tanks when power is cheaper and serve wash-down and cleaning loads from storage, so water heating stays off the peak.
Each tank is assembled on site from panels, so it fits tight utility rooms. Add tanks as the herd or the operation grows.
Heat recovered from milk cooling, an air-to-water heat pump or PowerPanel PVT charges the Thermal Tank, ideally off peak.
A 350-gallon tank stores about 54.6 kWh at a 35 °C differential; a 700-gallon tank stores 108 kWh. Add tanks as demand grows.
A load-side heat exchanger serves wash-down and cleaning water from storage, so equipment is sized for average demand, not the cleaning rush.
Existing water heaters stay in place for boost and backup. The engineer of record confirms final sizing, controls and how recovered heat ties into the system.
Recovered heat can charge the tank through a heat exchanger and be used later for wash-down and cleaning water. The project's engineer confirms how it ties into the existing refrigeration and water heating equipment.
Tanks charge when electricity is cheaper and serve hot water during peak periods, which keeps water heating off the peak. Savings depend on the farm's rate structure, which the utility sets.
Often, through utility programs and state or federal credits for heat pumps and efficiency upgrades. The Incentive Finder lists programs to check; the administrator and tax advisor decide eligibility.
Send us a message and our team of experts will get right back to you — or grab a time on our calendar below.